Nuvologic product · Custom PLC for OEMs and machine builders

Customized Nuvologic PLCs for machine builders

Built around your machine. Custom PLC hardware and control firmware for OEMs and machine builders who make special-purpose machines in repeat batches. Start from the NX-2AI-IOT reference configuration, with 24 V DC I/O, Modbus RTU, ASCII and TCP, and MQTT or HTTP(S) for IoT. We then tailor the I/O, control sequence and interfaces to your machine, with your own branding if you want it.

Choose your route

Four PLC routes, and which ones we offer

“Customized PLC” can mean different things. Here is what each route means at Nuvologic, who writes the control logic, and its status today, so you can enquire about the right one.

Offered Starting point

Reference configuration

The NX-2AI-IOT series: 8 digital inputs and 8 digital outputs at 24 V DC, 2 analog inputs, communication options by configuration.

Control logic
Written by Nuvologic as application firmware
Fits when
Your machine’s I/O fits the reference set

Final I/O and ratings are confirmed for the selected model.

Offered Core offer

Customized PLC hardware

I/O count and signal types, interfaces, form factor and branding adapted to your machine.

Control logic
Written by Nuvologic as application firmware
Fits when
You build the same machine repeatedly

White-label branding and manufacturing support available.

Offered Core offer

Application-specific firmware

The control logic, written around your machine’s operating sequence, sent to us as a description or a flowchart.

Control logic
Nuvologic
Later changes
How they are made is agreed with you in the technical review

Operator software (.NET dashboards) can be added. See an example.

Ask us Not a published feature

Customer-programmable PLC

Your own team programs the controller, for example in ladder logic or another IEC 61131-3 language, with a standard PLC tool.

Control logic
Your team
Status
Not offered as a standard feature today

If your team must program the controller, name your tool and language in the enquiry. We confirm what is possible before you commit.

PLC panel assembly is a separate job. Building the electrical panel around the controller is not part of the PLC offer. If your project needs one, mention it and we will tell you what we can support.

Safety functions such as emergency stops or guard interlocks belong in a safety-rated circuit and are assessed separately. Say so in your enquiry if your machine has them.

Intended buyers

Who should enquire

A customized controller makes most sense when the same machine or equipment is built repeatedly.

  • Machine OEMs who build machines repeatedly and want a controller matched to their I/O and functions.
  • Equipment manufacturers who want a controller designed around their product.
  • Automation integrators with repeat applications that a standard controller does not fit well.

Example applications

Where a customized controller can help

Typical cases. Tell us about your machine and we will say plainly whether a customized controller pays off.

  • Special-purpose machines built in repeat batches with a known I/O set.
  • Equipment controllers where the controller is part of the product you sell.
  • Machines that report to an HMI or a supervisory system over a defined connection.
  • Replacing an oversized controller with one matched to the machine’s actual I/O.

Reference design · NX-2AI-IOT series

Start from the reference configuration

A proven starting point. Then the I/O, the control sequence and the interfaces are tailored around your machine.

  • 08Digital inputs24 V DC
  • 08Digital outputs24 V DC, up to 700 mA per channel
  • 02Analog inputs0–10 V or 0–20 mA

Connectivity options

  • Ethernet
  • RS-485
  • CAN bus
  • USB
  • Wi-Fi
  • Bluetooth LE

Protocols

  • Modbus RTU
  • Modbus ASCII
  • Modbus TCP
  • MQTT
  • HTTP / HTTPS

Modbus RTU and ASCII run over RS-485, Modbus TCP over Ethernet. Availability depends on the selected configuration. Final I/O and features depend on the model and the agreed scope.

Operating temperature
0 to 70 °C
Protection
IP20, for mounting inside a control panel
Size
About 157 × 110 × 58.9 mm
  • Custom hardware

    I/O and interfaces tailored to your machine.

  • Application firmware

    Control logic built around your operating sequence.

  • OEM support

    White-label branding and manufacturing support.

Machine software

The operator software, on the same team

Real-time monitoring, parameter control and measurement analytics built around a customized Nuvologic controller. Below: the operator console of an inspection system, deployed in India.

Operator console, parameters view: gauges and readouts for bore, journal and height with pass or fail lamps
01 Parameters: live monitoring and control of bore, journal and height, with verdict lamps.
Operator console, mastering view: master values and an OK status
02 Mastering
Operator console, bore trend view: stability status, range and concentricity readouts
03 Bore trend
  • Customized PLC hardware, firmware and machine software from one team
  • .NET-based dashboards; other software stacks supported
  • Real-time monitoring, diagnostics, trends and pass/fail visualisation
  • Machine-specific parameter set-up, configuration and reporting
  • For inspection systems, automation machines and OEM platforms

Choosing

Customized or off-the-shelf PLC?

A standard PLC is often the right answer. A customized controller earns its development cost when the same machine is built again and again.

An off-the-shelf PLC usually fits when

  • You build one machine, or only a few
  • Standard I/O modules match your machine without much unused capacity
  • Your team or integrator already programs a particular PLC brand
  • Your customer specifies the controller brand

A customized controller is worth considering when

  • You build the same machine repeatedly, so the controller cost counts in every unit
  • Your I/O count or signal types do not match standard modules
  • Panel space or the form factor is tight
  • You want a simpler operator interface, or your own branding on the controller
  • You want control over the controller’s design and supply for the life of the machine

Where the break-even lies depends on your quantity and the development cost. We work it out with you in the technical review. More on the trade-offs: Customized PLC or off-the-shelf PLC: how to decide.

Customer inputs

What to send us

These details let us review your requirement properly. Share what you have. Three matter most: the I/O list, a description or flowchart of the machine sequence, and the interfaces the controller must talk to. Attach them to the enquiry form as one file of up to 5 MB, such as a PDF, Excel sheet or ZIP. Please leave out confidential drawings until an NDA is agreed.

  • 01Digital I/ONumber and type of digital inputs and outputs.
  • 02Analog signalsAnalog inputs and outputs, with their signal ranges.
  • 03SupplyThe supply voltage available on the machine.
  • 04CommunicationConnections needed, for example to an HMI, drives or a supervisory system.
  • 05Machine sequenceWhat the controller must do, as a description or flowchart.
  • 06Operator interfaceDisplay or operator-panel needs, if any.
  • 07Mounting and environmentEnclosure, mounting constraints and operating conditions.
  • 08Quantity and timelineExpected quantity per year and when you need the first units.

I/O list template. An Excel workbook with the I/O list, communication and machine details laid out for you. Fill it in and attach it to your enquiry. Not sure how detailed to be? Read how to write an I/O list for a customized PLC.

Download (Excel, 7 KB)

I/O configurator

Sketch your controller

It starts at the NX-2AI-IOT reference configuration: 8 digital inputs, 8 digital outputs and 2 analog inputs. Set the I/O, communication and supply your machine needs; the summary goes straight into the enquiry form, so the first conversation starts from your actual requirement.

List your digital and analog I/O, communication and supply in the enquiry form; the configurator needs JavaScript.

Technical data

Specifications

Values for the NX-2AI-IOT reference configuration. Ports depend on the configuration you choose. Supply voltage, analog outputs, enclosure and certifications are not published for the reference design; I/O, ratings and mounting are confirmed for your machine in the technical review.

Request the product brochure

Platform

Base platform
NX-2AI-IOT series reference design, tailored to your machine

Inputs and outputs

Digital inputs
8 × 24 V DC
Digital outputs
8 × 24 V DC, up to 700 mA per channel (output driver IC rating)
Analog inputs
2 × 0–10 V or 0–20 mA
Tailoring
Figures are for the reference configuration. I/O count and types are adapted to your machine; final I/O depends on the selected model.

Communication

Ports
Ethernet, RS-485, CAN bus, USB, Wi-Fi and Bluetooth LE, depending on the configuration
Field protocols
Modbus RTU and Modbus ASCII over RS-485; Modbus TCP over Ethernet
IoT protocols
MQTT, HTTP and HTTPS

Programming and interface

Programming
Application firmware with your control logic, built by Nuvologic around your operating sequence
Machine software
Operator dashboards for live monitoring, parameters, trends and reports (.NET; other stacks supported)

Electrical and mechanical

Ingress protection
IP20: protected against finger contact, not against dust or water. Install inside a control panel or enclosure.
Operating temperature
0 to 70 °C
Dimensions
Approximately 157 × 110 × 58.9 mm

Ordering and support

OEM support
White-label branding and manufacturing support

Deliverables

What the technical review gives you

  • A controller configuration proposed for your I/O and communication
  • The customization scope, agreed with you
  • Specifications confirmed for your application: I/O, electrical ratings, communication and mounting
  • Validation of the configuration against your requirements
  • Supply and support arrangements, agreed with you

Related evidence

Control and power electronics by the same team

The Nuvologic team has built industrial control and power electronics such as these: analog I/O, isolated encoder interfaces, PID control, and Modbus over RS-485 and Ethernet.

DEPLOYEDInspection machine · India

Inspection system controller and operator software

Controller
Customized Nuvologic PLC hardware and control firmware
Software
.NET operator console: bore, journal and height gauging with pass/fail verdicts, mastering and trends

See the operator console Read the case file

CASE 01Industrial weighing

In Motion Weighing

I/O
Multiple analog inputs and outputs, isolated encoder interfaces
Control
PID control, device control and logging
Comms
RS485, RS232, Ethernet; Modbus RTU and TCP

Read the case file

CASE 04Power electronics

Battery Charger

Protection
Over-current, short-circuit and reverse polarity
Configuration
Two or four channels, expandable in multiples of two

Read the case file

Project details

Process

How it works

  1. 01

    Requirement review

    Your I/O, communication, sequence and quantities.

  2. 02

    Controller proposal

    A suitable controller configuration and any customization, discussed with you.

  3. 03

    Validation

    The configuration is checked against your requirements.

  4. 04

    Supply and support

    Supply and support arrangements agreed with you.

FAQs

Customized PLC questions

Not answered here? Ask in your enquiry, or call +91 73500 20304.

Do you assemble PLC panels?

The core offer is the controller and its control firmware. If your project also needs a panel, mention it in your enquiry and we will confirm what we can support.

Who writes the PLC program for my machine?

Nuvologic builds the application firmware: the control logic, written around your machine’s operating sequence. Send the sequence as a description or a flowchart. If your team prefers to maintain the logic itself, say so and we agree how in the technical review.

Which programming languages does the controller use?

The control logic runs as application firmware that Nuvologic builds for your machine. If your team needs to change the logic itself later, tell us what you use today and we agree the approach in the technical review.

What are the I/O ratings?

In the NX-2AI-IOT reference configuration: 8 digital inputs at 24 V DC; 8 digital outputs at 24 V DC, each rated up to 700 mA by its output driver IC; and 2 analog inputs for 0–10 V or 0–20 mA signals. The I/O count and types can be tailored to your machine.

Which communication protocols does it support?

Modbus RTU and Modbus ASCII over RS-485, and Modbus TCP over Ethernet, for HMIs, drives, meters and supervisory systems. For IoT and cloud connections, MQTT, HTTP and HTTPS. Ports include Ethernet, RS-485, CAN bus, USB, Wi-Fi and Bluetooth LE, depending on the configuration.

Where can the controller be installed?

Inside a control panel or enclosure. It is rated IP20: protected against finger contact, but not against dust or water. It operates from 0 to 70 °C and measures about 157 × 110 × 58.9 mm.

What information do you need to start?

Your I/O count and types, communication needs, a description of the machine sequence and the expected quantity. The list above covers everything that helps.

Is there a minimum quantity?

Quantities and supply terms are agreed for each application. Include your expected annual quantity in the enquiry.

Can the controller carry our brand?

Yes. White-label branding is part of the OEM support, with manufacturing support as well, so the controller your customers see can carry your name.

What if I need fully custom control electronics?

If a board designed from scratch suits you better than a PLC, see embedded product design and hardware and PCB design.

Enquiry

Discuss a customized PLC

Share your I/O, communication and sequence requirements, and the quantity you expect. You can attach your I/O list or sequence flowchart to the form (one file, up to 5 MB).

  1. An engineer replies within one working day, by email or phone.
  2. We discuss a controller configuration and any open points.
  3. We agree scope, supply and support with you.

Send an enquiry

The topic is set to customized PLCs. You can change it.

    About the equipment

    About the controller

    About the project

    Scope needed (optional)

    Timeline, quotation or NDA (optional)

    We use these details only to respond to your enquiry. See our privacy policy.